TM 9-2350-261-34
SERVICE CHEMICAL FIRE EXTINGUISHER (M1059 ONLY) — Continued
0097 00
26. Clean gasket (8) and quad ring (9) with dry wiping rag. Inspect for cuts, breaks, wear, and elasticity.
27. Apply a thin coat of grease to gasket (8) surfaces.
28. Install gasket (8) and quad ring (9) on filler cap (10).
29. Ensure inside of shell (11) is clean and dry. Fill extinguisher with agent as required.
30. Install filler cap (10).
31. Lift puncture lever (12) and place hose (13) behind lever securing nozzle (14) in holder (15).
009700-7