11-6. OBSERVABLE
CONTROL BOX
TM 9-2350-273-BD
COMMUNICATIONS SYSTEM
SYMPTOM: THE INTERCOM DOES NOT WORK ON ANY
Detailed Assessment Steps:
1. Make sure the DC power is available to the turret by checking the dome light or
other electrical equipment in the turret.
2.
Make sure the MK-2096 Mini-Transient Voltage Suppressor is operational by
checking for a red light on the suppressor.
If the light is lit, replace or remove the
suppressor.
3.
Make sure that the MX-7777 or MX-7778 Transient Voltage Suppressor is
operational by depressing the Battle-Override switch. If the suppressor is bad, replace
or repair as necessary.
4.
Check that communication equipment is turned on and the switches are in the
proper positions. (Refer to para. 11-4.)
5.
Check that cables are connected to the proper connectors, correctly aligned, and
tightly connected to the receptacles.
6.
Jiggle the cables to check for intermittent opens or shorts.
a. If a defective cable is found, follow the procedures listed below:
(1) Replace the defective cable in accordance with standard repair
procedures.
(2) Replace the defective cable with an acceptable replacement cable
refer to para 11-34.
(3) Repair the defective cable in accordance with the repair procedures
in para. 11-30 or TM
-
9-2350-276-BD.
b.
If a defective cable is not found, then follow the
procedures in TM 11-5820-401-12.
troubleshooting
11-7. OBSERVABLE SYMPTOM:
THE INTERCOM WORKS ON SOME CONTROL
BOXES BUT NOT ALL
Detailed Assessment Steps:
1.
2.
and
Repeat steps 4 thru 6 in para. 11-6.
Replace CVC helmet and connecting
connecting cable.
cable with a known operational CVC helmet
11-7