TM-9-2350-273-BD

M48/M60 SERIES TANK, COMBAT FULL-TRACKED 105-MM GUN

TECHNICAL MANUAL; OPERATORS, ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE; BATTLEFIELD DAMAGE ASSESSMENT AND REPAIR

  TM-9-2350-273-BD - Page 78 of 288

TM 9-2350-273-BD
CHAPTER 5
COOLING SYSTEM
BDAR FIXES SHALL BE USED ONLY IN COMBAT
AT THE DISCRETION OF THE COMMANDER
AND SHALL BE REPAIRED BY STANDARD MAINTENANCE PROCEDURES
AS SOON AS PRACTICABLE AFTER THE MISSION IS COMPLETED.
SECTION I. General
5-1. General. Cooling system problems may be indicated by a variety of faults.
Typically the driver’s indicator panel will show overheating. However, sporadic
overheating or constant high temperature may indicate an impending major cooling
system problem.
5-2. Assessment Procedure
Damage found to:
-fans; . . . . . . . . . . . . . . . . go to Para 5-4
-fan drive; . . . . . . . . . go to Para 5-4
-shrouds; . . . . . . . . . . go to TM 9-2350-276-BD
-ducts; . . . . . . . . . . . . . go to TM 9-2350-276-BD
-engine . . . . . . . . . . . .
.go to TM 9-2350-276-BD
compartment covers;
-engine . . . . . . . . . . . .
.go to TM 9-2350-276-BD
compartment seals;
Damage found to:
-fan air intake; . . go to Para 5-4
-fan drive; . . . . . . . . go to Para 5-4
-engine . . . . . . . . . . . .
.go to TM 9-2350-276-BD
compartment covers;
-engine . . . . . . . . . . . .
.go to TM 9-2350-276-BD
compartment seals;
5-1


Back to Top