TM 9-2350-275-BD
COMMUNICATIONS SYSTEM
11-29.
COAXIAL CABLE REPAIR
General Information
This procedure gives instructions and identifies materials
coaxial or other shielded cables when standard replacement
Limitations:
●
None
Personnel/Time Required
●
1 soldier
●
20 minutes
Materials/Tools:
●
See illustrations in this procedure for materials required.
Other Option:
●
See shielded cable repair procedures in electrical chapter
Procedural Steps:
NOTE
recommended for repair of
parts are not available.
of TM 9-2350-276-BD.
Do not attempt to repair broken or damaged coaxial cables
unless absolutely necessary.
Replace the entire cable
whenever possible.
1.
If replacement is not practical, install a matching plug and jack of the proper size
and type for splicing the damaged or broken part.
11-41