TM 9-2350-275-BD
COMMUNICATIONS SYSTEM
11-34. FIELD EXPEDIENT RADIO REMOTE
General Information:
This procedure gives instructions for the construction of a field expedient remote to
replace the AN/GRA-39 if it is inoperative.
Limitations:
●
None
Personnel/Time Required:
●
1 soldier
●
60-90 minutes
Materials/Tools:
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
680 Ohm Resistor
47 Ohm Resistor
5000 Ohm Variable Potentiometer
H-144/U Handset (only cord and plug used)
M-80 Microphone (only cord and plug used)
TA-312/PT Field Telephones (two each)
Electrical tape
18-24 Gauge wire
Soldering iron and solder
Wire strippers
Multimeter or continuity tester
Knife
WD-1/TT field wire (as needed)
Procedural
Steps:
1. Build the prototype radio remote unit from the schematic using the following steps:
a.
Locate the R-3 potentiometer, K-1 relay, and BA4386/U battery. Tape the
three components solidly together.
b. Cut the cords from the H-144/U handset and the M-80 microphone.
11-47