TM-9-2350-277-10

CARRIER, M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; OPERATOR’S MANUAL

  TM-9-2350-277-10 - Page 552 of 889

TM 9-2350-277-10
TROUBLESHOOTING TABLE — Continued
0089 00
INITIAL SETUP:
Maintenance Level
Operator
NBC KIT
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
INSUFFICIENT AIR FLOW
AT ALL STATIONS.
1
. Checktoseeifspringclipisdownoverair
intake openings on air purifier.
Raisespringclipfromair
intake openings on air purifier
(WP 0081 00).
2.
Check to see if air hoses are kinked or
pinched.
Straighten or replace air hoses
(WP 0081 00).
3.
Check to see if it there are any loose hose
connections.
Tighten loose hose connections
(WP 0081 00).
2.
AIR FLOW TOO HIGH AT
ALL STATIONS.
1.
Check to see if air purifier is out of
adjustment.
If air purifier is out of adjustment,
notify unit maintenance.
3.
GAS PARTICULATE
FILTER WILL NOT
OPERATE WHEN SWITCH
IS IN ON POSITION.
1.
Check to see if AIR PURIFIER SWITCH is
in OFF position.
Turn AIR PURIFIER SWITCH to
ON.
2.
Check to see if ground wire is loose or
missing.
Notify unit maintenance of loose
or missing ground wire.
3.
Check to see if electrical cable assemblies
are loose or missing.
Notify unit maintenance.
0089 00-21/22 blank
Change 5


Back to Top