TM-9-2350-277-20-1

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 1 OF 6

  TM-9-2350-277-20-1 - Page 148 of 855

TM 9-2350-277-20-1
ENGINE OVERHEATS (NEW VSFD CONFIGURATION) — Continued
0014 01
7Y
1.
Engage variable speed fan drive manual override switch.
See TM 9-2350-277-10.
2.
Observe ventilating fan speed while helper (H) raises the
engine RPM to a high idle (1500 RPM) and allows the
engine to return back to idle.
3.
Does speed stay the same?
7YN
1.
Replace variable speed fan
drive manual override switch
(WP 0231 01).
2.
Verify no faults found.
8Y
1.
Observe rotation of ventilating fan (1) and generator drive
pulleys (2) on drive unit.
2.
Is fan pulley rotating as fast as the generator pulley?
8YN
1.
Disengage variable speed fan drive
manual override switch.
2.
Replace variable speed fan drive
(WP 0249 01).
3.
Verify no faults found.
001401-3
Change 5


Back to Top