TM 9-2350-277-20-1
ENGINE OVERCOOLS
0015 00
INITIAL SETUP:
Maintenance Level
Unit
Personnel Required
Mechanic
Helper (H)
References
TM 9-2350-277-10
Equipment Condition
Engine stopped (TM 9-2350-277-10)
Carrier blocked (TM 9-2350-277-10)
Power plant access panels open (TM 9-2350-277-10)
Power plant rear access panels removed (WP 0439 00)
Driver’s power plant access panel removed
(WP 0441 00)
Coolant TEMP indicator operation checked
(WP 0053 00)
T
WARNING
Moving parts of a power unit can seriously injure you. Clear
personnel away from power unit before startup. Stay clear of
moving parts when power unit is running.
1.
Start engine. See TM 9-2350-277-10.
2.
Observe speed of ventilating fan (1).
3.
Engage thermostatic fan speed switch (Old Configuration).
See TM 9-2350-277-10.
4.
Engage variable speed fan drive override switch (New
Configuration). See TM 9-2350-277-10.
5.
Did ventilating fan speed up when switch was engaged?
TN
1.
Stop engine. See TM 9-2350-277-10.
2.
Replace thermostatic fan speed
switch (WP 0231 00) (Old
Configuration).
3.
Replace variable speed fan drive
override switch (WP 0231 01)
(New Configuration).
4.
Verify no faults found.
001500-1
Change 5