TM-9-2350-277-20-1

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 1 OF 6

  TM-9-2350-277-20-1 - Page 386 of 855

TM 9-2350-277-20-1
TRANSMISSION DOES NOT PIVOT STEER
0071 00
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
Electrical Connector Pliers (WP 0926 00, Item 31)
General Mechanic’s Tool Kit (WP 0926 00, Item 65)
Multimeter (WP 0926 00, Item 30)
Personnel Required
Mechanic
Helper (H)
References
TM 9-2350-277-10
Equipment Condition
Engine stopped (TM 9-2350-277-10)
Carrier blocked (TM 9-2350-277-10)
Transmission in PV position
Power plant access door open (TM 9-2350-277-10)
T
1.
Remove harness 12349810 plug (1) from transmission jack (2).
2.
Turn MASTER SWITCH to ON. See TM 9-2350-277-10.
3.
Measure voltage between each socket on harness 12349810
plug (1) and ground. Multimeter should read 18 volts or
more at sockets B (3), D (4), and E (5), and 0 volts for
all remaining socket checks.
4.
Does multimeter indicate an incorrect reading?
TN
1.
Faulty transmission. Beyond unit
maintenance repair.
2.
Notify supervisor.
007100-1