TM-9-2350-277-20-1

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 1 OF 6

  TM-9-2350-277-20-1 - Page 430 of 855

TM 9-2350-277-20-1
PERSONNEL HEATER MALFUNCTIONS — Continued
0086 00
10Y
1.
Listen to heater until blower shuts off.
2.
Does blower shut off in less than 5 minutes?
10YN
1.
Replace heater (WP 0703 00
or WP 0704 00).
2.
Verify no faults found.
11Y
1.
Heater is operating properly.
2.
No faults found.
AY
1.
Remove heater control box (WP 0701 00).
2.
Check continuity on HI/LO switch between terminals
12 (1) and 13 (2).
3.
Does multimeter read 0 ohms?
AYN
1.
Replace heater HI/LO switch
(WP 0702 00).
2.
Verify no faults found.
A2Y
1.
Repair lead between heater switch and jack or heater switch
and ON/OFF/START switch (WP 0382 00).
2.
Verify no faults found.
008600-3
Change 5


Back to Top