TM-9-2350-277-20-1

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 1 OF 6

  TM-9-2350-277-20-1 - Page 452 of 855

TM 9-2350-277-20-1
POWER CONTROL ENCLOSURE A1 DC INPUT/OUTPUT INOPERATIVE (M1068A3
ONLY)—Continued
0090 00
Y
1.
Remove cable W4 plug P1 (1) from Power Control Enclosure
jack J25 (2).
2.
Measure voltage between center of P1 (1) and ground.
3.
Does multimeter read 22 volts DC or more?
YES
NO
YN
1.
Replace cable W4 (WP 0838 00).
2.
Verify no faults found.
0090 00-3


Back to Top