TM 9-2350-277-20-1
MSD/ICE TEST 70 STARTER SOLENOID VOLTAGE
0127 00
THIS WORK PACKAGE COVERS:
Test (page 0127 00-1).
INITIAL SETUP:
Maintenance Level
Unit
Personnel Required
Unit Mech 63T10
References
TM 9-2350-277-10
Equipment Condition
Engine stopped (TM 9-2350-277-10)
Vehicle blocked (TM 9-2350-277-10)
MSD/ICEhookeduptoDCA6(WP011700)
TEST
1.
Select
ICE Testing
from programs menu.
2.
Select button
1. Serial ICE
3.
Select button
1. ICE Tests
NOTE
All M113A3 variants are covered under
M113A3-M1068A3 APC
vehicle selection
4.
Select
M113A3-M1068A3 APC
, then select the
OK
button.
NOTE
Once MSD/ICE hook up screen
OK
button is selected, the MSD/ICE will perform a self test.
If self test fails, notify supervisor.
5.
Select
OK
button on the MSD/ICE hook up screen to proceed.
6.
Select
OK
button after successful self test.
7.
Follow on screen preparation for DCA offsets tests. Select
OK
button.
8.
Use Tab and Shift-Tab to move from one list box to another.
9.
Use spacebar to select/deselect the test.
10. Select
70 Starter Solenoid Volts
from
STARTING SYSTEM
list box. Select
Run Test(s)
button.
11. Turn MASTER SWITCH to ON. See TM 9-2350-277-10.
12. Press START switch for 3 seconds and observe MSD reading.
a.
If display reads 16 (volts) or more, test passes.
b.
If error message appears, see TM 9-6625-2301-14&P.
13. Turn MASTER SWITCH to OFF. See TM 9-2350-277-10.
14. Return to troubleshooting.