TM-9-2350-277-20-2

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 2 OF 6

  TM-9-2350-277-20-2 - Page 42 of 783

TM 9-2350-277-20-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS — Continued
0155 00
Table 16. Lubricants For Exposed Gear, Chain and Wire Rope Applications
LUBRICANT
EXPECTED TEMPERATURE
CW-IIC (O-203)
70 F to 120F(21Cto49 C)
CW-IIB (N/A)
30Fto90F(-1Cto32 C)
CW-II (MIL-PRF-18458) Lubricating Oil, Chain, Wire
Rope, and Exposed Gear
CW-IIA (O-199)
-30Fto50F(-34Cto10 C)
GO (MIL-PRF-2105) Lubricating Oil, Gear
Multipurpose
GO-75 (O-186)
-70Fto-10F(-57Cto23 C)
Table 17. Fluids For General Purpose Applications
LUBRICANT
EXPECTED TEMPERATURE
PL-S (MIL-PRF-32033) Lubricating Oil, General
Purpose, Preservative, Water Displacing, Low
Temperature
PL-S (O-190)
-70 F to 120F(-57Cto49 C)
PL-M (MIL-PRF-3150) Lubricating Oil, Preservative,
Medium
PL-M (O-192)
30Fto120F(-1Cto49 C)
EXPLANATION OF PMCS TABLE ENTRIES
(1)
Item Number Column
— Numbers in this column are for reference. When completing DA Form 2404 (Equipment
Inspection and Maintenance Worksheet), include the item number for the check/service indicating a fault. Item
numbers also appear in the order that you must do the checks and services for the intervals listed.
(2)
Interval Column
— This column tells you how often you must perform the checks/services. Semi-Annual
checks/services must be performed every six months or after 1500 (2400 km) of operation.
(3)
Man-Hour Column
— This column gives the man-hours (to the nearest 10th of an hour) needed to complete the
prescribed lubrication service. This column is used only for lubrication services.
(4)
Item To Be Checked or Serviced Column
— This column lists the item to be checked or serviced.
(5)
Crewmember/Procedure Column
— This column gives the procedure you must do to check or service the item
listed in the
Item To Be Checked or Serviced
column to know if the equipment is ready or available for its intended
mission or for operation. You must do the procedure at the time stated in the interval column.
(6)
Equipment Not Ready/Available If: Column
— Information in this column tells you what faults will keep your
equipment from being capable of performing its primary mission. If you perform check and service procedures
that show faults as listed in this column, do not operate the equipment. Follow standard operating procedures for
maintaining the equipment or reporting equipment failure.
0155 00-22
Change 5