TM-9-2350-277-20-2

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 2 OF 6

  TM-9-2350-277-20-2 - Page 43 of 783

TM 9-2350-277-20-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS — Continued
0155 00
Table 18. Semi-Annual Unit Level Preventive Maintenance Checks and Services for M113A3 FOV
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
1
Semi-
Annual
Road Test
CAUTION
Do not allow engine to operate for
prolonged periods if outside air
temperature is less than 85 F(29 C)
and gauge is above 200 F(93 C) or
outside air temperature is above 85 F
(29 C) and gauge is above 225 F
(100 C). Serious damage to engine may
result.
NOTE
Be sure that all operator level PMCS in
TM 9-2350-277-10 has been completed
prior to performing this PMCS. Any
non-mission capable faults must be
corrected prior to road test.
NOTE
Check instruments, gauges, and
warning lights for normal indications
as outlined in TM 9-2350-277-10.
NOTE
Review all operator recorded problems
prior to road test.
NOTE
When conditions prevent a road test,
perform engine idle test (Step 3a) and
governed no load test (Step 4a).
0155 00-23
Change 5


Back to Top