TM 9-2350-277-20-2
REPLACE AIR BOX HEATER IGNITION WIRE — Continued
0204 00
INSTALLATION
1.
Connect ignition wire (1) to ignition unit (5).
2.
Connect other end of ignition wire (1) to air box igniter (2).
3.
Secure ignition wire (1) to air pump wiring harness (4) with two new tie straps (3).
4.
Rotate solenoid receptacle (7) to original position. Tighten nut (6) 1/2 turn after contact.
FOLLOW-THROUGH STEPS
1.
Install power plant upper and lower rear access panels and support (see your -10).
END OF TASK
0204 00-2