15. Connect two circuit 40 leads (1) and (2) to lamp assembly (3).
16. Connect lead 33 (4) and special purpose harness lead 27B (5) to engine coolant temperature gauge (6).
17. Connect front main harness connector(7)tomainlightswitch(8)
.
18. Connect lead 450B (9), lead 450 (10), lead 451A (11), and lead 452A (12) to bilge pump switch (13).
19. Connect lead 452B (14) to bilge front pump ON indicator (15).
20. Connect lead 451B (16) to rear bilge pump ON indicator (17).
21. Connect special purpose harness lead 27A (18) and lead 28 (19) to fuel gauge (20).
22. Connect special purpose harness lead 459 (21) to master switch indicator (22).
FOLLOW-THROUGH STEPS
1.
Install two ground leads, mounts, and instrument panel on struts (WP 0295 00).
2.
Install tachometer and speedometer cables on instrument panel gauges (WP 0858 00).
3.
Connect battery ground strap (WP 0337 00 or WP 0338 00).
END OF TASK
0279 00-7/8 blank
Change 5