TM 9-2350-277-20-3
REPLACE INSTRUMENT PANEL ASSEMBLY (NEW CONFIGURATION) — Continued
0279 01
11. Connect lead 38 (51), lead 27P (52), lead 25A (50), and lead 27F (49) to special purpose cable.
12. Install glow plug indicator (46) and secure with knurled nut (43).
13. Connect lead 406 (53) and special purpose harness lead 27C (44) to glow plug switch (42).
14. Connect lead 31 (48) and lead 30 (47) to fuel tank switch (45).
15. Connect battery/generator harness lead 10 (40) and special purpose harness lead 27 (34) to circuit breaker (41).
16. Connect battery/generator harness lead 27E (39) to battery/generator gauge (35).
17. Connect lead 520 (36) and lead 19 (38) to blackout switch (37).
027901-7