TM-9-2350-277-20-3

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 3 OF 6

  TM-9-2350-277-20-3 - Page 157 of 941

TM 9-2350-277-20-3
REPLACE CIRCUIT BREAKER — Continued
0280 00
INSTALLATION
1.
Place circuit breaker (3) on rear of instrument panel. Secure with two screws (5) and new locknuts (4).
2.
Connect circuit 27 lead (2) and circuit 10 lead (1) to circuit breaker (3).
FOLLOW-THROUGH STEPS
1.
Install instrument panel (WP 0295 00).
2.
Connect battery ground strap (WP 0337 00), (WP 0338 00), or (WP 0339 00).
3.
Turn MASTER SWITCH to ON (see your -10). MASTER SWITCH ON light should come on (see your -10).
4.
Turn MASTER SWITCH to OFF (see your -10).
END OF TASK
0280 00-2