REPLACE INSTRUMENT PANEL BATTERY-GENERATOR GAUGE WIRING HARNESS
— Continued
0289 00
4.
Disconnect circuit 15 lead (1) from instrument panel wiring harness (2).
5.
Disconnect circuit 10 lead (3) from panel circuit breaker (4).
6.
Disconnect circuit 27E lead (5) from battery generator gage (6).
7.
Remove panel wiring harness (2) from instrument panel (7).
8.
Remove eight locknuts (8), washers (9), and screws (10). Separate master switch panel (11) from distribution box (12).
Discard locknuts.
9.
Remove screw (13), lockwasher (14), circuit 450A lead (15), and harness lead (16) from bus bar (17). Discard
lockwasher.
10. Remove panel wiring harness lead (16) from distribution box (12).
0289 00-3
Change 2