TM 9-2350-277-20-3
REPLACE FUEL RETURN PRESSURE TRANSDUCER — Continued
0325 00
INSTALLATION
WARNING
Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These
compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you
dizzy and irritate your eyes and throat.
Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes.
Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves.
1.
Apply a thin coat of adhesive to threads of transducer (3).
2.
Connect transducer (3) to tee (4).
3.
Connect fuel return pressure transducer lead (1) to MSD/ICE wiring harness (2).
FOLLOW-THROUGH STEPS
1.
Lower power plant grill (WP 0464 00).
2.
Install air cleaner (WP 0168 00).
3.
Close power plant access door. See TM 9-2350-277-10.
END OF TASK
0325 00-2
Change 5