REPLACE VARIABLE SPEED FAN DRIVE SENSORS AND SWITCHES (NEW
CONFIGURATION) — Continued
0321 01
INSTALLATION
1.
Install engine coolant sensor 3A3 (6). Connect variable speed wiring harness plug P6 (5)on engine coolant sensor
3A3 (6).
2.
Install engine running switch S2 (2) to tee (3) on secondary fuel filter (4). Connect variable speed wiring harness plug P3
(1) on engine running switch S2(2).
FOLLOW-THROUGH STEPS
1.
Connect battery ground strap (WP 0337 00), (WP 0338 00), or (WP 0339 00)
2.
Install driver’s power plant access panel (see your -10).
3.
Install power plant rear access panels (see your -10).
END OF TASK