TM 9-2350-277-20-5
REPLACE 5.0 KW AUXILIARY POWER UNIT (APU) (M577A3 AND M1068A3) — Continued
0675 01
INSTALLATION
1.
Install four screws (6), washers (4), new lockwashers (5), and remote panel (3) to inside forward vehicle bulkhead.
2.
Install electrical control cable (7) with grommet in vehicle through opening in upper engine bulkhead.
3.
Install electrical control cable (7) to remote panel (3) and secure with tie straps (8).
WARNING
Hanging loads, heavy parts, and overhead equipment can fall unexpectedly. Falling loads can
kill or injure personnel. Keep away from hanging loads, heavy parts, and overhead equipment.
Use correct lifting device to move loads. A helper is required as a guide when moving loads.
Keep hands and feet out of confined spaces from which heavy loads are being removed or
installed.
WARNING
Damaged slings can fail when loaded. Breaking slings can strike and injure personnel.
Suspended load can fall and crush personnel.
Inspect all slings before use. Do not use damaged slings. Clearly mark all damaged slings
as DAMAGED - DO NOT USE.
0675 01-4
Change 4