TM-9-2350-277-20-5

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 5 OF 6

  TM-9-2350-277-20-5 - Page 353 of 1047

TM 9-2350-277-20-5
REPLACE COOLANT HEATER FUEL INLET HOSE AND FITTINGS — Continued
0712 00
FOLLOW-THROUGH STEPS
1.
Open heater fuel shutoff valve. See TM 9-2350-277-10.
2.
Start coolant heater. See TM 9-2350-277-10. Check for fuel leaks. Turn heater off.
3.
Bleed fuel lines (WP 0679 00).
4.
Install air cleaner (WP 0168 00).
5.
Close power plant access door. See TM 9-2350-277-10.
6.
Start engine. See TM 9-2350-277-10.
7.
Raise and lock ramp. See TM 9-2350-277-10.
8.
Stop engine. See TM 9-2350-277-10.
END OF TASK
0712 00-4
Change 5