TM 9-2350-277-20-5
REPLACE COOLANT PUMP TO BATTERY BOX HOSES — Continued
0713 00
9.
Connect hose (15) to coolant pump shutoff valve (16) and secure with clamp (17).
10. Install two new straps (18) on hose (15).
FOLLOW-THROUGH STEPS
1.
Install air cleaner (WP 0168 00).
2.
Fill coolant heater system (WP 0710 00).
3.
Install batteries and retainers (WP 0346 00, WP 0347 00, WP 0348 00, or WP 0349 00).
4.
Start coolant heater. See TM 9-2350-277-10. Check for leaks. Turn heater off.
5.
Install driver’s compartment floor plates (WP 0453 00).
6.
Install power plant rear access panels (WP 0439 00).
7.
Close power plant access door. See TM 9-2350-277-10.
8.
Start engine. See TM 9-2350-277-10.
9.
Raise and lock ramp. See TM 9-2350-277-10.
10. Stop engine. See TM 9-2350-277-10.
END OF TASK
0713 00-6
Change 5