TM-9-2350-277-20-6

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 6 OF 6

  TM-9-2350-277-20-6 - Page 169 of 487

TM 9-2350-277-20-6
REPLACE OUTBACK REMOTE CABLE ASSEMBLY (M1068A3 ONLY) — Continued
0847 01
WARNING
Each Outback inverter assembly weighs 70 lbs (32kg) and may be awkward to handle. Use
correct lifting procedures, indicated lifting devices, and/or assistance from other personnel to
avoid injury. Failure to comply could result in injury to personnel and equipment damage.
NOTE
Both inverters are identical, however due to space constraints, one of the inverters must
be mounted upside down.
10. Slide inverter (IN1) mount assembly (20) into housing (19). Have helper assist.
11. Install three cap screws (21), new lockwashers (22), and flat washers (23) securing the inverter (IN1) mount assembly
(20) to the inverter housing (19).
0847 01-12
Change 5


Back to Top