TM 9-2350-277-20-6
REPLACE OUTBACK REMOTE CABLE ASSEMBLY (M1068A3 ONLY) — Continued
0847 01
INSTALLATION
WARNING
Each Outback inverter assembly weighs 70 lbs (32kg) and may be awkward to handle. Use
correct lifting procedures, indicated lifting devices, and/or assistance from other personnel to
avoid injury. Failure to comply could result in injury to personnel and equipment damage.
NOTE
Connect the cable leads to the inverter by positioning inverter half out of inverter housing or
connect cable leads before placing inverter assembly into housing.
1.
Loosen two screws (30) on cable clamp (31) located on side of inverter housing (24) enough to route cable (11) through
cable clamp up to terminal block (27). Do not tighten cable clamp screws until leads are secured to terminal block.
2.
Loosen four terminal block screws (28). Connect four leads (29) into inverter terminal block (27) and tighten terminal
screws (28). Follow wiring diagram (32).
0847 01-8
Change 5