TM-9-2350-277-20-6

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 6 OF 6

  TM-9-2350-277-20-6 - Page 155 of 487

TM 9-2350-277-20-6
REPLACE CASCADE REMOTE HARNESS (M1068A3 ONLY) — Continued
0847 00
1.
Remove access cover (12) on inverter housing A2 (15) by removing 10 screws (13) and lockwashers (14). Discard
lockwashers.
2.
Remove 10 screws (1), and lockwashers (2), from faceplate (3). Lower faceplate (3) to gain access to RP1 harness
(7). Discard lockwashers.
3.
Remove nut (6) and safety cover (5) from terminal 2 on meter M1 (4).
4.
Loosen captive screws on connectors and disconnect RP1 harness connectors (10) from inverters (11).
5.
Remove four locknuts (8), screws (9), and RP1 remote harness (7) from faceplate (3). Remove harness. Discard locknuts.
0847 00-2
Change 5


Back to Top