TM 9-2350-277-20-6
REPLACE MSD/ICE SHUNT (M113A3 AND M1059A3 ONLY) — Continued
0870 00
4.
Install lead 770 (13), new lockwasher (14), and screw (15) on shunt (5).
5.
Remove tape from battery lead (16) and install lead on shunt (5). Secure with two screws (17) and new lockwashers (18).
6.
Install battery ground strap (19), new lockwasher (20), and screw (21) to shunt (5).
FOLLOW-THROUGH STEPS
1.
Connect battery ground strap (WP 0337 00).
2.
Install shunt guard (WP 0868 00).
3.
Close spall liners. See TM 9-2350-277-10.
END OF TASK
0870 00-5/6 blank
Change 5