TM 9-2350-277-20-6
REPLACE MSD/ICE CREW WIRING HARNESS (M113A3 AND M1059A3
ONLY) — Continued
0878 00
3.
Connect plug (6) to connector (1).
4.
Position wiring harness (7) along hull. Secure with 21 clamps (8), washers (9), new lockwashers (10), and screws
(11). Have helper assist.
087800-5
Change 5
2.
Install connector (1) on bulkhead (2) in power plant compartment. Secure with four screws (3), washers (4), and new
locknuts (5).