TM-9-2350-277-20-6

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 6 OF 6

  TM-9-2350-277-20-6 - Page 319 of 487

TM 9-2350-277-20-6
REPLACE MSD/ICE CREW WIRING HARNESS (M113A3 AND M1059A3
ONLY) — Continued
0878 00
5.
Install battery ground lead (12), lead 779 (13), and battery ground lead (14) on battery terminal (15). Secure with
screw (16) and nut (17).
FOLLOW-THROUGH STEPS
1.
Install shunt leads (WP 0870 00).
2.
Install shunt guard (WP 0868 00).
3.
Install battery box covers. See TM 9-2350-277-10.
4.
Close power plant front access door. See TM 9-2350-277-10.
END OF TASK
0878 00-6
Change 5