TM 9-2350-277-34
INSTALL PERSONNEL HEATER KIT (M113A3, M1059A3, AND M58 ONLY) — Continued
0072 00
25. Secure fuel pump (1) to threaded bracket (2) with four lockwashers (3), two flat washers (4), and screws (5).
NOTE
Shielded lead must be secured to weldnut to ensure proper grounding and operation of fuel
pump.
26. Secure shielded lead (6) to weldnut (7) with washer (8), two lockwashers (9), and screw (10).
0072 00-7