TM-9-2350-311-10

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; OPERATOR’S MANUAL

NOVEMBER 1994

  TM-9-2350-311-10 - Page 103 of 775

TM 9-2350-311-10
2-5
LEAKAGE DEFINITIONS - CONTINUED
b.
Class II. Leakage of fluid great enough to form drops but not enough to cause drops to drip from item being
checked/inspected.
c.
Class III. Leakage of fluid great enough to form drops that fall from the item being checked/inspected.
NOTE
M182 only: Leakage of 1 ml (approximately 25 drops) is permissible at the seal interface to the
variable recoil rods after five (5) rounds or 24 hours after firing.
2-6 DAMAGE DEFINITIONS
Damage definitions are as follows:
a.
Blowby. Powder markings beyond a sealing surface.
b.
Burrs. A raised portion, restricting the entrance of a part, component, or assembly.
c.
Cracks. A narrow break or separation in material.
d.
Gouges. A groove or cavity in a sealing surface that cannot be repaired.
e.
Nicks. An indentation caused by object(s) striking the material.
Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR M109 SELF-PROPELLED HOWITZER
Item
No.
Interval
1
2
Before
Before
Location
Item to Check/
Service
Vehicle
Subfloor Drain
Plugs and Access
Cover Plates
DRIVER
2-18 Change 2
Crewmember
Procedure
DRIVER
Walk around vehicle. Check for any obvious fluid
leakage, missing items, or damage to equipment.
Do not ford if any drain plugs are missing to
prevent water damage to equipment.
Check all drain plugs (1) and cover plates (2) for
installation.
Not Fully Mission
Capable If:
Any Class III oil,
fuel, or coolant
leak found.
Any drain plug
(1) or cover plate
(2) is missing.


Back to Top