TM-9-2350-311-10

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; OPERATOR’S MANUAL

NOVEMBER 1994

  TM-9-2350-311-10 - Page 105 of 775

TM 9–2350–311–10
2–20
Table 2–1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR M109 SELF-PROPELLED HOWITZER — CONTINUED
Location
Item
No.
Not Fully Mission
Capable If:
Crewmember
Procedure
Item to Check/
Service
Interval
5
Before
Radiator
DRIVER
Check coolant level in radiator. Add coolant as
needed.
Any coolant leak
exists or radiator
cap (1) is mis-
sing.
1
6
Before
Driver’s Compart-
ment Fire
Extinguisher
Handle
DRIVER
Check to ensure fire extinguisher handle (1) is
properly seated and laced with wire seal (2).
Wire seal (2) is
broken, missing,
or fire extinguish-
er handle (1) is
pulled.
1
2
7
Before
Neutral Safety
Switch
DRIVER
WARNING
To prevent injury, make sure all personnel are
a safe distance from vehicle.
Make sure parking brake is engaged. Pull fuel
shutoff control assembly out. Place vehicle in first
gear. Attempt to start engine.
Engine cranks.
Notify unit
maintenance.


Back to Top