TM 9-2350-311-10
Item
No.
15
lnterval
Before
Table 2–1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR M109 SELF-PROPELLED HOWITZER
— CONTINUED
Location
Item to Check/
Service
Hydraulic
Power Pack
Reservoir (Cont)
Crewmember
Procedure
CHIEF OF SECTION
a.
b.
c.
d.
e.
f.
g.
Place utility pail under sight gage (1) drain.
Turn pointer handle (6) at bottom of sight gage
(1) to OFF position.
Remove plug from elbow at bottom of sight
gage (1).
Turn pointer handle (6) at bottom of sight gage
(1) to DRAIN position and drain hydraulic fluid.
When oil level is correct turn pointer handle (6)
to OFF position.
Replace plug on elbow.
Turn pointer handle (6) to GAGE position.
NOTE
Dispose of hydraulic fluid in accordance with
local regulations.
h. Discard drained hydraulic fluid. Do not reuse.
Not Fully Mission
Capable If: