TM 9-2350-311-10
Item
No.
17.1
18
2-34
Interval
Before
Before
Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR M109 SELF-PROPELLED HOWITZER - CONTINUED
Location
Item to Check/
Service
Variable Recoil
Assembly
Cannon
Equilibrator
Change 2
Crewmember
Procedure
CHIEF OF SECTION
Before firing, there shall be no more than 1 ml
(approximately 25 drops) of oil accumulation at
any seal interface location and no evidence of
seepage of hydraulic fluid from any of the hy-
draulic tubes, manifolds, hose connections,
and fill bleeder valves.
Check for oil accumulation at seal interface(s) and
for any hydraulic leaks.
GUNNER AND ASSISTANT GUNNER
NOTE
Ensure that equilibrated elevation cylinder has
been equilibrated.
a. Unlock travel lock assembly, check power eleva-
tion operation at gunner’s control assembly (1).
b. Check manual and power elevation operation at
assistant gunner’s control (2).
Not Fully Mission
Capable If:
Cannon assembly
will not elevate.
Neither elevation
method works.