TM 9-2350-311-10
Item
No.
17
Interval
Before
Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR M109 SELF-PROPELLED HOWITZER - CONTINUED
Location
Item to Check/
Service
Replenisher
Accumulator
Assembly
Pressure (Cont)
Crewmember
Procedure
CHIEF OF SECTION
b. Fill M3 oil gun (3) as follows:
1. Turn handle (4) of M3 oil gun (3) counter-
clockwise as far as it will go. Loosen locking
screw (5) on head (6) of M3 oil gun.
2. Unscrew and remove head (6) and handle
(4) as a unit from body (6.1). Be sure cap (7)
is on M3 oil gun (3).
Do not clean body of M3 oil gun with solvent.
3. Inspect inside of body (6.1) of M3 oil gun (3)
for cleanliness and clean as necessary.
4. With opening held upright and at an angle to
reduce air entering body (6.1), fill body of M3
oil gun (3) with hydraulic fluid (item 20, Appx
D).
5. Install head (6) and handle (4) as a unit, and
tighten locking screw (5).
6. With nozzle end of M3 oil gun (3) held up-
right, remove cap (7) from nozzle and allow
air to escape for a minute or two.
7. Purge remaining air from M3 oil gun (3) by
turning handle (4) until no more air bubbles
appear at nozzle.
Not Fully Mission
Capable If:
Change 2 2-31