TM 9-2350-311-10
Item
No.
17
lnternal
Before
Table 2–1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR M109 SELF-PROPELLED HOWITZER —
CONTINUED
Location
Item to Check/
Service
Replenisher
accumulator
Assembly
Pressure
Crewmember
Procedure
CHIEF OF SECTION
To prevent damage to equipment, make sure
M3 oil gun is loaded with hydraulic fluid (item
20, Appx D) and not lubricating oil.
NOTE
Replenisher accumulator assembly (1) pres-
sure gage (2) reading (before firing) should be
17 to 24 psi (117 to 165 kPa). Pressure may
increase during normal firing due to heat ex-
pansion. Safe-to-fire range is 17 to 50 psi (117
to 344 kPa).
During firing, be sure that replenisher accumulator
assembly (1) pressure gage (2) shows a pressure
of 17 to 50 psi (117 to 344 kPa). If pressure is lower
or higher, add or bleed hydraulic fluid from replen-
isher accumulator assembly. When replenisher ac-
cumulator assembly pressure gage reading
is low, add hydraulic fluid (item 20, Appx D) to the
replenisher accumulator assembly as follows:
a. Place cannon assembly at zero elevation.
Not Fully Mission
Capable If:
2-30