TM 9-2350-311-10
Item
No.
17
2-32
Interval
Before
Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR M109 SELF-PROPELLED HOWITZER - CONTINUED
Location
Item to Check/
Service
Replenisher
Accumulator
Assembly
Pressure (Cont)
Crewmember
Procedure
CHIEF OF SECTION
c. Fill replenisher accumulator assembly (1) as
follows:
1. Using adapter, hose, and reducer, attach M3
oil gun (3) loosely to filling valve (8), turn
handle (4) clockwise until clean liquid flows
around filling valve. Tighten reducer to filling
valve.
2. Fill replenisher accumulator assembly (1) at
filling valve (8) using M3 oil gun (3) until
pressure gage (2) reads 17 to 24 psi (117 to
165 kPa).
Not Fully Mission
Capable If: