TM-9-2350-311-10

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; OPERATOR’S MANUAL

NOVEMBER 1994

  TM-9-2350-311-10 - Page 115 of 775

TM 9–2350–311–10
2–29
Table 2–1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR M109 SELF-PROPELLED HOWITZER — CONTINUED
Location
Item
No.
Not Fully Mission
Capable If:
Crewmember
Procedure
Item to Check/
Service
Interval
16
Before
Hydraulic
Filter
Assemblies
(M109A4/M109A5)
CHIEF OF SECTION
Before firing, check bypass indicator (1) on hydrau-
lic filter assembly (2). Filters are clean and
functioning if red button is flush with bypass
indicator. If red button is protruding from bypass
indicator, hydraulic filter assemblies are dirty and
hydraulic fluid is bypassing them.
Hydraulic fluid is
bypassing the
hydraulic filter
assemblies (2).
1
2


Back to Top