TM 9-2350-311-10
Item
No.
50
51
Interval
After
After
Table 2–1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR M109 SELF-PROPELLED HOWITZER — CONTINUED
Location
Item to Check/
Service
Fan (Radiator)
Torsion Bars
Crewmember
Procedure
DRIVER
To prevent injury or death to personnel, keep
hands and loose clothing away from fans
when engine is running.
a.
b.
c.
d.
Open air intake grille and transmission access
doors.
Check for coolant leaks and serviceability of
hoses.
Inspect fans (1) for missing or damaged impel-
lers. Damage includes cracked, chipped, or bro-
ken impellers. If impellers are damaged, notify
unit maintenance.
Start engine, Check for oil leaks at fan drive.
Check that both fans (1) are turning. If both fans
are not turning, shut down engine and notify unit
maintenance.
Not Fully Mission
Capable If:
Class Ill leak is
found.
Fan (1) impellers
are missing,
cracked, chipped,
or broken.
Either fan (1)
does not turn
when engine is
running.
DRIVER
Check for broken torsion bars by prying up road
wheel.
Any torsion bar is
broken or mis-
sing.
2-70