TM-9-2350-311-10

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; OPERATOR’S MANUAL

NOVEMBER 1994

  TM-9-2350-311-10 - Page 261 of 775

TM 9--2350--311--10
Change 6
2--163
2--12 PREPARATION FOR FIRING — CONTINUED
2--12.1
Pre-Firing Emplacement — Continued
c. Emplacing Infinity Aiming Reference M1A1/M1A2 Collimator — Continued
(f)
Ensure azimuth adjustment is in center of the traversing capabilities by operating the azimuth
adjustment knob (56).
NOTE
M1A2 only has an on/off switch for the light sequence.
(g) Turn switch (56.1) ON.
(h) Loosen azimuth adjustment clamping knob (57). Sighting down front and rear sights (58), rough lay
M1A1/M1A2 collimator (21) on M117/M117A2 panoramic telescope (36) objective lens. Tighten
azimuth adjustment clamping knob. Adjust M1A1/M1A2 collimator elevation as required and tighten
elevation adjustment clamping knob (55).
(i)
Loosen cross-level clamping knob (59). Rotate M1A1/M1A2 collimator (21) until bubble in
cross-level vial (60) is centered. Tighten cross-level clamping knob.
2
Sighting through M117/M117A2 panoramic telescope (36), gunner rotates azimuth knob (44) until
M1A1/M1A2 collimator (21) is sighted.
36
44


Back to Top