TM-9-2350-311-10

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; OPERATOR’S MANUAL

NOVEMBER 1994

  TM-9-2350-311-10 - Page 349 of 775

TM 9--2350--311--10
Change 3
2--251
2--17 OPERATING AUXILIARY EQUIPMENT — CONTINUED
2--17.1
Personnel Heater (P/N 11669489--1 and 11669490--1) — Continued
b. Shut-Down
WARNING
To prevent injury to personnel, do not use the MASTER switch to shut the personnel heater
down. Fuel vapors will accumulate in the ventilating air circuit, and the personnel heater may
also be damaged by reverse burning.
Shutting Down Hupp and Stewart Warner Heaters
To stop personnel heater operation, move the HEATER switch (2.1) to the OFF position. The blower will continue to
operate for approximately 3 minutes to allow the system to cool. If blower continues to operate or otherwise
malfunctions, notify unit maintenance.
Shutting Down Global Heaters
Move HEATER switch (2.1) to OFF position. Global heater will enter purge mode and after four minutes it will
automatically shutdown.
2
1
STEWART-WARNER
HUPP
GLOBAL
2.1


Back to Top