TM 9--2350--311--10
Change 6
3--21
3--5
HULL MAINTENANCE PROCEDURES — CONTINUED
3--5.4
Maintenance of Air Cleaner
a. Removal
WARNING
If NBC exposure is suspected, all filter media will be handled by personnel wearing full NBC
protective equipment.
NOTE
Depending on conditions, the air cleaner filter must be removed periodically for cleaning. Loss
in engine power, an overheating engine, or excessive black exhaust may indicateneed formore
frequent cleaning. If air cleaner indicator shows red area, the air cleaner is restricted and air
cleaner filters must be checked.
1
Shut off engine.
2
Remove hull ammunition rack (1) by disconnecting two quick-release pins (2) and lifting straight up.
3
Remove right access door (3) by pulling locking latch (4) down and lifting off right access door.
CAUTION
Do not pull left access door up so far that it causes binding and damage to left access door when
removing.
4
Remove left access door (5) by pulling locking latch (6) down, pulling left access door up slightly, and
sliding left access door off to right.
5
Pull locking levers (7) down.
6
Push air cleaner filter (8) in and pull out from air cleaner filter compartments (9).


Back to Top