TM 9-2350-311-20-1
3-3 TROUBLESHOOTING CHART —
CONTINUED
r.
ENGINE OIL PRESSURE GAGE CIRCUIT —
ENGINE OIL PRESSURE INDICATOR FAILS TO
CONTINUED
OPERATE WITH ENGINE RUNNING; ALL OTHER
INSTRUMENTS OPERATE — CONTINUED
CONTINUED FROM STEP H
T
-
1 Reconnect engine disconnect-to-bulkhead
2.
3.
4.
5.
6.
wiring harmess to drivers bulkhead.
Disconnect engine disconnect-to-bulkhead
wiring harness from engine disconnect.
Turn MASTER switch ON and check
ENGINE OIL PRESSURE gage for a
reading.
If ENGINE OIL PRESSURE gage shows a
maximum reading, place a jumper wire from
socket D (lead 36) to ground.
Check gage for reading.
Turn MASTER switch OFF.
Does ENGINE OIL PRESSURE gage show minimum
when grounded and maximum when not grounded?
I
Repair or replace lead 36 from engine
disconnect-to-bulkhead wiring harness
(para 8-45, M109A2/M109A3; para
8-46, M109A4/M109A5).
Repair or replace lead 36 of powerplant
wrong harness (para 8-43, M109A2/
M109A3; para 8-44, M109A4/M109A5).
END OF TASK