TM 9-2350-311-20-1
CONTINUED FROM STEP D
E
1.
2.
3.
4.
5.
Reconnect portable instrument panel
wiring harness to portable instrument
panel disconnect.
Disconnect lead 27 of bulkhead-to-portable
instrument panel harness from circuit
breaker output.
Place red lead of multimeters in circuit
breaker output and black lead to ground.
Turn MASTER switch ON and check for
voltage.
Turn MASTER switch OFF.
I
Is voltage present?
Repair or replace lead 27 from
bulkhead-to-portable instrument
panel wiring harness (para 849).
F
3.
4.
5.
Reconnect lead 27 to circuit breaker output.
Disconnect lead 10 from circuit breaker”
input.
Place red lead of multimeters in lead 10
and black lead to ground.
Turn MASTER switch ON and check for
voltage.
Turn MASTER switch OFF.
Is voltage present?
Replace circuit breaker (para 8-33,
M109A2/M109A3; para 8-34,
M109A4/M109A5).
Troubleshoot master relay circuit
(para 3-3b).
3-223


Back to Top