TM 9-2350-311-20-1
3-3 TROUBLESHOOTING CHART — CONTINUED
q. TRANSMISSION OIL PRESSURE INDICATOR
TRANSMISSION OIL PRESSURE INDICATOR NEEDLE
CIRCUIT — CONTINUED
FAILS TO MOVE OR IS UNSTEADY; ALL OTHER GAGES
OPERATE PROPERLY — CONTINUED
CONTINUED FROM STEP D
I
F
1. Reconnect lead 27 to circuit breaker output.
2. Disconnect lead 10 from circuit breaker
input.
3. Place red lead of multimeters in lead 10
and black lead to ground.
4. Turn MASTER switch ON and check for
voltage.
5. Turn MASTER switch OFF.
Is voltage present?
(para 3-3b)
Troubleshoot master relay circuit
Replace circuit breaker (para 8-33,
M109A2/M109A3; 8-34, M109A4/M109A5).
I
3-214