TM-9-2350-311-20-1

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL FOR HULL, POWERPLANT, DRIVE CONTROLS, TRACKS, SUSPENSION, AND ASSOCIATED COMPONENTS

AUGUST 1994

  TM-9-2350-311-20-1 - Page 314 of 1275

TM 9-2350-311-20-1
3-3 TROUBLESHOOTING CHART — CONTINUED
q. TRANSMISSION OIL PRESSURE INDICATOR
TRANSMISSION OIL PRESSURE INDICATOR NEEDLE
CIRCUIT — CONTINUED
FAILS TO MOVE OR IS UNSTEADY; ALL OTHER GAGES
OPERATE PROPERLY — CONTINUED
CONTINUED FROM STEP D
I
F
1. Reconnect lead 27 to circuit breaker output.
2. Disconnect lead 10 from circuit breaker
input.
3. Place red lead of multimeters in lead 10
and black lead to ground.
4. Turn MASTER switch ON and check for
voltage.
5. Turn MASTER switch OFF.
Is voltage present?
(para 3-3b)
Troubleshoot master relay circuit
Replace circuit breaker (para 8-33,
M109A2/M109A3; 8-34, M109A4/M109A5).
I
3-214


Back to Top