3-3 TROUBLESHOOTING CHART —
CONTINUED
q. TRANSMISSION OIL PRESSURE INDICATOR
TRANSMISSION OIL PRESSURE INDICATOR NEEDLE
CIRCUIT — CONTINUED
FAILS TO MOVE OR IS UNSTEADY; ALL OTHER GAGES
OPERATE PROPERLY — CONTINUED
CONTINUED FROM STEP A
I
Reconnect lead 321 to transmission oil
B
1.
pressure transmitter.
2. Disconnect lead 321 from TRANSMISSION
OIL PRESSURE gage.
3. Turn MASTER switch ON and check
TRANSMISSION OIL PRESSURE gage for
a reading.
4. If TRANSMISSION OIL PRESSURE gage
shows a maximum reading, use a jumper
wire to ground gage.
5. Check gage for reading.
6. Turn MASTER switch OFF.
Does TRANSMISSION OIL PRESSURE gage show
minimum when grounded and maximum when not
grounded?
1. Reconnect lead 321 to TRANSMISSION OIL
C
PRESSURE gage.
2. Disconnect lead 27 from TRANSMISSION
OIL PRESURE gage.
3. Place red lead of multimeters in lead 27 and
black lead to ground.
4. Turn MASTER switch ON and check for
voltage.
5. Turn MASTER switch OFF.
Is voltage present?
PORTABLE
INSTRUMENT PANEL
3-212


Back to Top