TM 9-2350-311-20-1
CONTINUED FROM STEP D
E
1. Reconnect portable instrument panel wiring
harness to portable instrument panel
bracket.
2. Disconnect lead 27 from circuit breaker
output.
3. Place red lead of multimeters in circuit
breaker output and black lead to ground.
4. Turn MASTER switch ON and check for
voltage.
5. Turn MASTER switch OFF.
is voltage present?
Repair or replace lead 27 of bulkhead-
to-portable instrument panel wiring
harness (para 8-49).
F
1. Reconnect lead 27 to circuit breaker output.
2. Disconnect lead 10 from circuit breaker
input.
3. Place red lead of multimeters in lead 10
and black lead to ground.
4. Turn MASTER switch ON and check for
voltage.
5. Turn MASTER switch OFF.
Is voltage present?
Replace circuit breaker (para 8-33,
M109A2/M109A3; 8-34, M109A4/M109A5).
3-205