TM 2350-311-20-1
CONTINUED FROM STEP D
E
1. Reconnect bulkhead-to-engine bracket
wiring harness to engine disconnect bracket.
2. Disconnect lead 352B from aeration
detector.
3. Place a jumper wire from lead 352B to
ground.
4. Turn MASTER switch ON and press
COOLANT indicator light.
5. Turn MASTER switch OFF.
Does COOLANT indicator light operate?
I
Repair or replace lead 352B of
powerplant wiring harness (para
8-43, M109AZM109A4; 8-44,
M109A4/M10A5).
Replace aeration detector (para 8-16).
END OF TASK
3-199