TM 9-2350-311 -20-1
3-3 TROUBLESHOOTING CHART — CONTINUED
o. ENGINE WATER TEMP INDICATOR CIRCUIT —
(2) ENGINE LOW LEVEL COOLANT LIGHT FAILS TO
CONTINUED
LIGHT WHEN PRESSED-TO-TEST; ALL OTHER
LIGHTS OPERATE
CONTINUED FROM STEP F
1.
2.
3.
4.
5.
Reconnect lead 27 to COOLANT indicator
light.
Disconnect lead 27 from circuit breaker
output.
Place red lead of multimeter in circuit
breaker output and black lead to ground.
Turn MASTER switch ON and check for
voltage.
Turn MASTER switch OFF.
Is voltage present?
I
1. Reconnect lead 27 to circuit breaker output.
2. Disconnect portable instrument panel wiring
harness from portable instrument panel
bracket.
3. Place a jumper wire from socket P (lead
4596) to socket C (lead 459).
4. Place red lead of multimeter in socket A
(lead 27).
5. Turn MASTER switch ON and check for
voltage.
6. Turn MASTER switch OFF.
Is voltage present?
CONTINUED ON NEXT PAGE
3-194